<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15179</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: no plate on unload table
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
3230/3244 Trendsetter Autoloader: This error is reported at the start of a process command, if
the vacuum reading on the unload cups is below threshold ("al uvt").  Check the vacuum level with
the "table" command.  This error may also reported during punching, if the plate does not cover
the sensor at the end of the unload table when being pushed for the first time into the punch.  This
sensor is the "plate eject sensor" displayed with the "table" command.
</text></DescriptionText>
<DescriptionText><text>
Platesetter_3244:
This error is reported at the start of a process command, if
plate_loc u (3) is not zero (empty), Or the table sensor sensor is not be sensing a plate (if enabled)
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume.
</text></DescriptionText>
<DescriptionText><text>
Platesetter:
Lift the bridge and open the front door, make sure there is a plate on the unload table
and that it is in contact with the table
and is not curled from being left on the drum too long.
</text></DescriptionText>
</OperatorAction>
<Cause>
3244 Platesetter: The plate_loc u (3) may not be zero (empty), Or the
table sensor sensor may not be sensing a plate (if enabled).
</Cause>
<Cause>
3230/3244 Trendsetter Autoloader: Incorrect vacuum reading.
</Cause>
<Cause>
3230/3244 Trendsetter Autoloader: Faulty optical sensor on unload table, or bad wiring.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_nups.xml</LinkAddress><LinkTitle>NVS: al nups</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_uvs.xml</LinkAddress><LinkTitle>NVS: al uvs</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cfg_uvt.xml</LinkAddress><LinkTitle>NVS: al uvt</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_pes.xml</LinkAddress><LinkTitle>NVS: al pes</LinkTitle></Link>
<Link><LinkAddress>../commands/table.xml</LinkAddress><LinkTitle>Command: table</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:54 2008 PST
</Updated>
<Links>
</Links>
</Error>